On this page
- Diagnosis summary
- Safety and classification scope
- Definition (Reference)
- Typical Presentation (Informative)
- Field Identification Cues (Normative)
- Surface-catch class (MSRT)
- Reveal / lighting / geometry
- Location / access
- Classification Mapping (to VIS-DA) (Normative)
- Indicative Relief / Depth (Informative)
- Differentiation & False Positives (Informative)
- Evidence Package (Documentation Requirements) (Normative)
- Mis-ID Pitfalls (Informative)
- Reporting Language (Template)
- Related glossary terms
- Related DSS
- Source and version
DAMAGE SPECIFICATION STANDARD / METHOD-AGNOSTIC
DSS-M.01.01 — Scraper/Razor Scoring
Mechanical scoring on the worked surface - appearance-based classification; acceptance per VIS §6
Diagnosis summary
Linear score(s) produced by blades/scrapers/razors or sharp edges contacting the glass face, typically presenting bright “chip flanks”/micro-chipping along the line in raking light. Distinct from coating anomalies (area sheen/colour change) and from non-directional residue films. Terminology for micro-chipping and chip flank follows VIS §3;

Definition (Reference)
ReferenceLinear score(s) produced by blades/scrapers/razors or sharp edges contacting the glass face, typically presenting bright “chip flanks”/micro-chipping along the line in raking light. Distinct from coating anomalies (area sheen/colour change) and from non-directional residue films. Terminology for micro-chipping and chip flank follows VIS §3; classification is appearance-based using surface-catch and morphology under VIS viewing conditions.
Typical Presentation (Informative)
Informative- One or more straight or gently arced lines; often directional with sparkling edges in raking light due to chip flanks.
- Persists after Non-Invasive Reveal (clean & dry); unlike residue, the cue does not wipe off.
- Can occur as single tracks, clustered short scores, or parallel passes (e.g., blade at a guide).
Field Identification Cues (Normative)
NormativeSurface-catch class (MSRT)
- SC-2 (clear) is common for true blade scores; shallow grazes may read SC-1 (slight). Perform one light, non-marring pass only; MSRT supports classification, not acceptance.
Reveal / lighting / geometry
- Complete Non-Invasive Reveal (distilled/neutral-pH water, lint-free microfiber; no blades/abrasives/chemicals before evaluation). Inspect at 12 / 36 / 72 in, normal incidence + oblique sweep (~60°-120°) under raking light.
Location / access
- Confirm the cue is on the exposed face (not between panes). If any doubt, use parallax (between-pane features show fixed parallax) and record surface numbering #1-#4.
Classification Mapping (to VIS-DA) (Normative)
Normative- CAT-2 - Light: Narrow, fine-edged lines with SC-1, no pronounced chip flanks; limited impact at standard view.
- CAT-3 - Moderate: SC-2 with minor chip flanks; line(s) noticeable at standard distance.
- CAT-4 - Severe: SC-2 (clear-to-strong); rough chip flanks, possible pits/craters; distinctly visible at standard and wide-field views. (Use VIS visibility convention and MSRT outcome; “linear directionality with chip flanks suggests mechanical history.”)
Indicative Relief / Depth (Informative)
Informative- CAT-2: ~0.2-1 μm typical surface incision (clean edges; no pronounced flanks).
- CAT-3: ~1-5 μm with incipient micro-chipping along flanks.
- CAT-4: ≥5 μm with rough chip-flank breakout; local pits/craters may be present.
(Depths are illustrative for cueing only; VIS classification/acceptance remains appearance-based.)
Differentiation & False Positives (Informative)
Informative- vs. Coating anomalies (Co-family): Coating rub/patch/colour shift is area-based, SC-0/SC-1, and lacks chip flanks; worked-surface coating anomalies are not permitted at acceptance.
- vs. Residue films/overspray (R-family): Residues change with reveal; a true score persists.
- vs. Glass-on-glass tracks (M.01.03): Tracks often appear as paired arcs/lines with alternating intensity; confirm chip flanks for scraper scoring.
- vs. Between-pane features (A-family): Internal cues show fixed parallax → CAT-5 by location.
Evidence Package (Documentation Requirements) (Normative)
Normative- Photo set (VIS): 12 / 36 / 72 in, normal + oblique, include raking; add macro frames of the line showing chip flanks without a worked transition edge. Note reveal status and lighting/time.
- MSRT result: Record SC class (often SC-2); one pass, non-marring.
- Forms: Pane ID; surface numbering; worked surface Y/N; geometry checklist; photos attached (per VIS Appendix X3 fields).
Mis-ID Pitfalls (Informative)
Informative- Attempting to “feather” a score during inspection can create a worked region/transition edge, which VIS disallows at acceptance for CAT-0...CAT-4. Keep evaluation non-marring and appearance-only.
Reporting Language (Template)
Template- M.01.01 Scraper/Razor Scoring - Linear line(s) at #__ with chip-flank sparkle in raking; MSRT = SC-2 (clear). Persists after Non-Invasive Reveal. Classified CAT-2/3/4 by visibility and flank severity per VIS. Photo set at 12/36/72 in (normal + oblique + raking); surface numbering and form fields recorded. Acceptance per VIS §6 (appearance-based).
Related glossary terms
- ScrapeGRK-106
- Raking lightGRK-129
- ChipGRK-034
- Coating rubGRK-115
- AbrasiveGRK-168
Source and version
GlassRenu Damage Specification Sheets (DSS), DSS-M.01.01. Source revision and extraction date are recorded in the deployment manifest.
Open the complete published DSS with table of contents (PDF)
Normative and informative labels are preserved from the source. The downloadable one-sheet is a condensed classification aid; this web page retains the complete source-based specification content.