DAMAGE SPECIFICATION STANDARD / METHOD-AGNOSTIC

DSS-A.02.02 — Bubbles / Stringers (entrapped gas/voids in laminated interlayer)

Assembly / internal condition - typically CAT-5 by location; out of in-place scope

DSS-A.02.02Assembly / Internal ConditionsSource-based page complete
Download DSS one-sheet (PDF)One-page US Letter · selectable text · print ready

Diagnosis summary

Discrete bubbles (rounded voids) or stringers (elongate/filamentary voids) within the laminated interlayer (between plies). These are laminate-internal features—not on an exposed worked face—and are therefore not addressable in place; classification is location/condition-driven. Product/spec context for laminated glass: ASTM C1172; ISO 12543.

Created colored-pencil technical illustration for DSS-A.02.02 — Bubbles / Stringers (entrapped gas/voids in laminated interlayer)
Image created by GlassRenu for use in this document. This illustration shows the visual characteristics of Bubbles / Stringers (entrapped gas/voids in laminated interlayer).

Definition (Reference)

Reference

Discrete bubbles (rounded voids) or stringers (elongate/filamentary voids) within the laminated interlayer (between plies). These are laminate-internal features-not on an exposed worked face-and are therefore not addressable in place; classification is location/condition-driven. Product/spec context for laminated glass: ASTM C1172; ISO 12543. Surface numbering: identify as laminate-internal (distinct from #1/#4 and IGU #2/#3 faces).

Typical Presentation (Informative)

Informative
  • Isolated, round entrapped gas pockets; or linear “stringers” oriented with cut/lay-up flow.
  • Concentrated near edges/corners, along insert/print boundaries, or sporadically in field.
  • No change after Non-Invasive Reveal of exposed faces; no worked transition edge on the face. (Reveal & inspection geometry per VIS §5.)

Field Identification Cues (Normative)

Normative

Location / access (primary):

  • Confirm laminate-internal location. On project forms, record product family (laminated) and surface numbering (#1-#4; laminate-internal). Do not assign face numbers to laminate-internal interfaces unless a project spec requires it.

Surface-catch class (MSRT):

  • SC-0 (none) on the exposed face(s). MSRT is a single, non-marring pass used only to support classification-not acceptance. Do not abrade.

Inspection environment / reveal controls:

  • Perform Non-Invasive Reveal (clean & dry) prior to evaluation; persistence confirms non-face location. Avoid blades/abrasives/chemicals prior to classification.

Viewing / lighting:

  • VIS geometry: 12 / 36 / 72 in; normal incidence + oblique sweep (~60°-120°) with raking light. Back-lit frames can help show void boundaries.

Classification Mapping (to VIS-DA) (Normative)*

Normative
  • CAT-5 - Out of in-place scope when features are laminate-internal (not on an exposed worked surface). Document and refer per project protocol (fabricator/manufacturer/warranty).

Indicative Relief / Depth (Informative)

Informative
  • Not applicable to the exposed face (no measurable surface relief; SC-0). Numeric μm depth ranges apply to face-side defects only.

Differentiation & False Positives (Informative)

Informative
  • vs. Seeds/blisters in float glass (P.02.02): Factory gas inclusions within monolithic glass; encapsulated and SC-0 on the face; classify under processing feature entries, not laminated interlayer.
  • vs. Adhesive/film domes (R-family) on #1/#4: Face-side residues respond to Non-Invasive Reveal; laminate-internal bubbles do not.
  • vs. Local delamination (A.02.06): Delamination often shows defined boundary (Newton fringes/iridescence) or creep; bubbles/stringers are discrete voids without broad separation. (Use VIS geometry + reveal to separate.)

Evidence Package (Documentation Requirements) (Normative)*

Normative
  • Photo set (VIS): 12 / 36 / 72 in, normal + oblique, raking; add one back-lit close-up (when safe) to show void boundaries.
  • Forms: Pane ID; product family & surface numbering (#1-#4; laminate-internal); worked surface Y/N; functional coating present on worked surface? (Y/N/Unknown); reveal status; lighting/time; geometry checklist.
  • Measurements (if requested): Approximate void size (mm), count per area, and distance from edge; note temperature/RH at time of inspection (for reproducibility). (Use VIS forms fields; add notes.)

Mis-ID Pitfalls (Informative)

Informative

Attempting “spot-work” on the face to address an internal void risks creating a worked region (visible transition edge) that VIS disallows at acceptance for CAT-0...CAT-4. Keep classification appearance-only and location-based; refer.

Reporting Language (Template)

Template
  • A.02.02 Bubbles/Stringers (laminate-internal) - Discrete voids within interlayer; no change after Non-Invasive Reveal; MSRT = SC-0 on exposed faces; documented at 12/36/72 in with normal + oblique under raking. CAT-5 (laminate-internal; out of in-place scope). Refer per project protocol.

Related glossary terms

Source and version

GlassRenu Damage Specification Sheets (DSS), DSS-A.02.02. Source revision and extraction date are recorded in the deployment manifest.

Open the complete published DSS with table of contents (PDF)

Normative and informative labels are preserved from the source. The downloadable one-sheet is a condensed classification aid; this web page retains the complete source-based specification content.

Download DSS one-sheet (PDF)PDF ID: DSS-A.02.02 · Version 1.3.1